Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : HongCe
Model Number : L-Z-2×1200
Certification : Third party calibration certificate
Place of Origin : China
MOQ : 1 set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 120 days
Packaging Details : Plywood
Price : Negotiatable
Cycle time : 10min/pcs
Leak rate : 1.0E-6mbar.l/s
Test pressre : 5bar
Vacuum pump : Leybold
PLC : Omron
Automatically Vacuum Helium Leak Detection Equipment for Cast-Aluminium Shell of Switch Gears
The cast-aluminium shell shall be filled with SF6 gas, no leak is permitted. As there might have casting defects, it is necessary to do leak test before SF6 fill. The normal solution is auto vacuum chamber helium leak test system.
Test Concept
Charge high pressure gas into the product for gross leak test and proof test;
Evacute the vacuum chamber.
Vent gas from the product.
Evacuate the product and charge helium into the product.
Test the helium signal from the vacuum chamber by the leak detector for fine leak judge.
Recover helium from the product.
Vent vacuum chamber.
Technical specification:
Cycle time:10min/pcs. (for reference, demanded by customer)
Leak rate:1.0E-6mbar.l/s. (for reference, demanded by customer)
Test pressre:5bar. (for reference, demanded by customer)
Main parts of system:
Vacuum pump | Leybold |
Vacuum sensor | Inficon |
Helium leak detector | Inficon |
Presure sensor | GE |
Solenoid valve | Burkert |
PLC | Omron |
HMI | Omron |
Helium recovery unit | HJ |
Other Else Helium Leak Test Machine for Cast-Aluminium Shell of Switch Gears
Patent Certificate:
International Clients:
![]() |
Automatic Vacuum Helium Leak Testing Equipment for Cast-Aluminium Shell Switch Gears with Inficon Detector Omron PLC Images |